Huzhou Mingyao Import and Export Co., Ltd.  |  Industrial instruments & power equipment sourcing
sales@mingyaotrade.com  |  WhatsApp +86 182 9710 9629

Thermocouple

Thermocouple
Temperature Instruments

Thermocouple

MINGYAO thermocouples (K, J, E, T, N, S, B, R types) deliver fast response and stable readings for furnaces, boilers, ovens and process pipelines. Available with armored, insulated and threaded/flanged housings to meet diverse industrial conditions.

Trade term: FOB / CIF. MOQ 20 pcs per model. Lead time 3–7 working days for standard models, 15–30 days for customized builds. Payment 50% T/T deposit, balance against copy of B/L.

Specifications

GraduationK (WRN) / N (WRM) / E (WRE) / J (WRF) / T (WRC) / S (WRP) / R (WRQ) / B (WRR)
Measuring rangeK 0 ~ 1300 °C; N 0 ~ 1200 °C; E 0 ~ 800 °C; J 0 ~ 750 °C; T -40 ~ 350 °C; S / R 0 ~ 1600 °C; B 600 ~ 1700 °C
Tolerance Class IK / N: ±1.5 °C (-40 ~ 375 °C), ±0.004|t| (375 ~ 1000 °C); S: ±1 °C (0 ~ 1100 °C), ±[1+0.003(t-1100)] °C (1100 ~ 1600 °C)
Tolerance Class IIK / N: ±2.5 °C (-40 ~ 333 °C), ±0.0075|t| (333 ~ 1200 °C); S: ±1.5 °C (0 ~ 600 °C), ±0.0025|t| (600 ~ 1600 °C)
Sheath diameterArmoured: Φ0.25 ~ Φ8 mm single element, Φ3 ~ Φ8 mm double element; assembled: Φ16 / Φ20 mm
Sheath material1Cr18Ni9Ti (≤ 600 °C), GH3030 / Inconel600 (≤ 800 °C), GH3039 / alumina (≤ 1100 °C)
Insulation resistance≥ 1000 MΩ·m at 500 VDC, 20 ± 15 °C, RH ≤ 80 %
Response time τ0.5Φ3: 0.6 s grounded / 1.2 s ungrounded; Φ4: 0.8 / 2.5 s; Φ5: 1.2 / 4.0 s; Φ6: 2.0 / 6.0 s; Φ8: 4.0 / 8.0 s
JunctionGrounded, ungrounded or exposed hot junction
Process connectionM20×1.5, M27×2, G1/2, fixed thread, movable flange, fixed flange
TransmitterHead-mounted 4-20 mA transmitter optional (model suffix B)
StandardsIEC 60584, GB/T 18404, GB/T 30429, JB/T 5582

Values above are taken from the manufacturer datasheet for this series. The exact model, range and options are confirmed on the order confirmation, and a signed datasheet plus test report is supplied with the shipment.

Applications

  • Heat treatment furnaces, kilns and sintering lines
  • Boilers, steam headers and heat exchangers
  • Chemical reactors, cracking and reforming units
  • Metallurgy, glass and cement high-temperature zones
  • Flue gas, exhaust and oven temperature profiling

Features

  • Class I tolerance with ±0.004|t| above 375 °C for K and N types
  • Armoured sheath down to Φ0.25 mm, bendable on site
  • Grounded junction for fast response, ungrounded for electrical noise
  • High-purity alumina and GH3039 protection tubes for 1100 °C service
  • Minimum insertion depth 8–10 times the sheath diameter
  • Head-mounted transmitter turns the mV signal into 4-20 mA / HART

Reference: IEC 60584 / GB/T 18404 thermocouple tables; calibration certificate by lot. Certificates are offered only where available for the selected model.