Our RTD probes use Pt100 elements with excellent repeatability and long-term stability, suitable for HVAC, machinery, chemical and food processing. Custom probe lengths, connection heads and cable lengths are available.
Trade term: FOB / CIF. MOQ 20 pcs per model. Lead time 3–7 working days for standard models, 15–30 days for customized builds. Payment 50% T/T deposit, balance against copy of B/L.
| Element | Pt100 (Pt500 / Pt1000 and Cu50 on request) |
|---|---|
| Measuring range | Pt100 -200 ~ +850 °C (assembled); armoured version -200 ~ +500 °C |
| Tolerance Class A | ±(0.15 + 0.002|t|) °C, valid up to 650 °C |
| Tolerance Class B | ±(0.30 + 0.005|t|) °C |
| Element resistance | R0 = 100 ± 0.06 Ω (Class A) / 100 ± 0.12 Ω (Class B); W100 = R100/R0 = 1.3850 |
| Wiring | 2-wire, 3-wire (standard) or 4-wire |
| Sheath diameter | Φ2 ~ Φ16 mm (armoured), Φ16 / Φ20 mm (assembled) |
| Sheath material | 1Cr18Ni9Ti, SUS304, SUS316L; ceramic element former inside |
| Insulation resistance | > 100 MΩ at 10 ~ 100 VDC, 15 ~ 35 °C, RH ≤ 80 % |
| Response time τ0.5 | Ceramic element < 0.15 ~ 0.5 s; assembled probe typically < 15 s; bearing type < 5 s |
| Process connection | M12×1.5, M16×1.5, M20×1.5, M27×2, flange, clamp (sanitary) |
| Protection | IP65 (flameproof housing); IP54 for polycarbonate housing |
| Transmitter | Integral 4-20 mA / HART temperature transmitter optional |
Values above are taken from the manufacturer datasheet for this series. The exact model, range and options are confirmed on the order confirmation, and a signed datasheet plus test report is supplied with the shipment.
Reference: IEC 60751 platinum resistance; IEC 751 / JB/T 8622 selection data. Certificates are offered only where available for the selected model.