Compensation cable and wire for K type thermocouples, matching the thermoelectric curve over the working temperature range so the cold junction error stays small. PVC insulation for general use or fluoroplastic for heat resistance up to 200 C, copper braid or tinned copper braid shielding, steel tape or steel wire armor, intrinsic safety version for hazardous areas.
Trade term: FOB / CIF. MOQ 20 pcs per model. Lead time 3–7 working days for standard models, 15–30 days for customized builds. Payment 50% T/T deposit, balance against copy of B/L.
| Type | KX compensation wire and cable for K type thermocouple, precise grade |
|---|---|
| Executive standard | GB/T 4989-2013, JB/T 7495-2014 |
| Construction | 2 cores or 2 pairs, twisted; 2 x 0.5 / 1.0 / 1.5 mm2 |
| Insulation / sheath | PVC for general use 70 C or 105 C; fluoroplastic for heat resistance up to 200 C |
| Shielding | Copper wire braid (P), tinned copper braid, individual plus overall braid, copper tape |
| Armor | Steel tape (22) or steel wire (32) |
| Laying temperature | PVC 0 C minimum; fluoroplastic -15 C minimum |
| Bending radius | 16 x OD for copper tape shielded; 10 x OD for other constructions |
| Accuracy | Precise grade, matched to the K type thermoelectric curve |
| Options | Flame retardant ZR prefix; intrinsic safety ia prefix for Ex areas |
Values above are typical ranges for this product family. Final specifications are confirmed against the model data sheet before quotation; dimensional drawings and test reports are provided on request.
Reference: GB/T 4989-2013 compensation cable standard; JB/T 7495-2014. Certificates are offered only where available for the selected model.