Instrument and computer cable for analogue signals, DCS and PLC wiring where interference rejection matters. PE or XLPE insulated pairs, 1 to 24 pairs with 2 or 3 cores each, 0.5 to 2.5 mm2, copper braid and/or aluminium foil shielding with drain wire, steel tape or steel wire armor, and an intrinsically safe version for hazardous areas.

Trade term: FOB / CIF. MOQ 20 pcs per model. Lead time 3–7 working days for standard models, 15–30 days for customized builds. Payment 50% T/T deposit, balance against copy of B/L.

Specifications

Rated voltage300/500 V, AC 50 Hz
Executive standardTICW6-2009, JB/T 13486-2018, enterprise standard
Pair number1 ~ 24 pairs
Cores per pair2 cores (2-wire group) or 3 cores (3-wire group)
Conductor cross-section0.5, 0.75, 1.0, 1.5, 2.5 mm2
InsulationPE standard; XLPE, PVC, silicone or fluoroplastic on request
SheathPVC, or PE / halogen-free polyolefin
ShieldingCopper braid overall (P), braid individual (P1), copper-plastic tape (P2), aluminium-plastic tape (P3), individual plus overall
ArmorSteel tape (22) or steel wire (32)
Insulation resistancePVC 25 MOhm.km minimum; PE / XLPE 3000 MOhm.km minimum at 20 C
Withstand voltage1000 V for 1 minute, no breakdown
Capacitance / inductanceCore to core 90 pF/m maximum; 0.6 uH/m maximum (intrinsic safety type)
Working temperaturePE 70 C; XLPE 90 C; silicone 180 C; fluoroplastic 200 C

Values above are taken from the manufacturer datasheet for this series. The exact model, range and options are confirmed on the order confirmation, and a signed datasheet plus test report is supplied with the shipment.

Applications

  • 4 ~ 20 mA and thermocouple signals into DCS and PLC racks
  • Metering and analyser loops in chemical plants
  • VFD and motor feedback encoder wiring
  • Intrinsically safe loops in Zone 0 / Zone 1 areas
  • Laboratory and test-bench signal transmission

Features

  • Twisted pairs with individual and overall shield stop crosstalk
  • Drain wire makes shield grounding simple
  • Intrinsic safety version with low capacitance and inductance
  • Aluminium foil plus braid for RF-heavy substation rooms
  • Steel tape armor for buried signal trunks
  • Pair counts to 24 cover a full I/O marshalling panel

Reference: TICW6-2009 and JB/T 13486-2018; intrinsic safety version for Ex ia loops. Certificates are offered only where available for the selected model.