Pressure transmitters convert gauge, absolute or differential pressure into 4-20mA, HART or fieldbus signals. Stainless steel diaphragms, wide range selection and anti-corrosion options suit oil, gas, water and chemical applications.
Trade term: FOB / CIF. MOQ 20 pcs per model. Lead time 3–7 working days for standard models, 15–30 days for customized builds. Payment 50% T/T deposit, balance against copy of B/L.
| Series | TK3051 (CD differential / CG gauge / CA absolute / L level) |
|---|---|
| Reference accuracy | ±0.025 %, ±0.05 %, ±0.075 % or ±0.1 % of calibrated span |
| Range | 100 Pa ~ 40 MPa (expandable to 60 MPa); turndown up to 100:1 |
| Output | 4-20 mA DC two-wire, linear or square-root, HART digital signal superimposed |
| Supply | 12 ~ 45 VDC (24 VDC nominal) |
| Long-term stability | ±0.15 % of URL over 5 years |
| Static pressure | 14 MPa standard, 32 MPa for high-static-pressure version |
| Process temperature | -40 ~ 104 °C with silicone fill; -18 ~ 85 °C with inert fill |
| Ambient temperature | -40 ~ 85 °C without LCD; -30 ~ 60 °C with LCD |
| Diaphragm | 316L stainless steel, Hastelloy C, Monel, tantalum or gold-plated |
| Damping | 0.2 ~ 1.67 s adjustable; start-up < 2 s, no warm-up |
| Explosion-proof | Ex d IIB T4 ~ T6 flameproof; Ex ia IIC T5 intrinsically safe |
| Protection | IP65 |
| Diagnostics | Continuous self-diagnosis, alarm output < 3.8 mA or > 22 mA |
| Standards | EMC per GB/T 18268 / EN 61326-1 |
Values above are taken from the manufacturer datasheet for this series. The exact model, range and options are confirmed on the order confirmation, and a signed datasheet plus test report is supplied with the shipment.
Reference: GB/T 18268 EMC and EN 61326-1; Ex d IIB T4-T6 / Ex ia IIC T5 certificates by model. Certificates are offered only where available for the selected model.