Level gauges provide direct, visual indication of liquid level in tanks and vessels. Magnetic flap and sight-glass types with optional alarm switches and remote transmission, suitable for chemical, oil and water tanks.
Trade term: FOB / CIF. MOQ 20 pcs per model. Lead time 3–7 working days for standard models, 15–30 days for customized builds. Payment 50% T/T deposit, balance against copy of B/L.
| Series | UHZ-518 / 517 magnetic flap level gauge, side or top mounted |
|---|---|
| Measuring range (centres) | 300 ~ 6000 mm standard; up to 15 000 mm on special order |
| Accuracy | ±10 mm (10 mm flap), ±16 mm (16 mm flap) |
| Nominal pressure | PN1.0 ~ PN10.0 MPa; high-pressure version up to 32 MPa |
| Medium temperature | -20 ~ +250 °C standard; up to +450 °C with heat-dissipating design |
| Medium density | ≥ 0.45 g/cm³, float matched to the actual density |
| Density difference | ≥ 0.15 g/cm³ for interface measurement |
| Medium viscosity | ≤ 0.4 Pa·s; heating jacket for viscous or crystallising media |
| Body material | 304 / 316L / PTFE-lined / PP; PTFE-lined to 2.5 MPa, PP to 1.0 MPa |
| Process connection | DN25 / DN50 flange per HG/T 20592, ANSI or DIN on request |
| Transmitter | 4-20 mA two-wire magnetic or reed transmitter, HART optional |
| Alarm | Magnetic memory high / low limit switches |
| Protection | IP65; Ex ia IIC T4 intrinsically safe version available |
| Follow speed | ≤ 0.08 m/s; vibration ≤ 25 Hz, amplitude ≤ 0.5 mm |
Values above are taken from the manufacturer datasheet for this series. The exact model, range and options are confirmed on the order confirmation, and a signed datasheet plus test report is supplied with the shipment.
Reference: HG/T 21584 magnetic level gauge standard; HG/T 20592 flange standard. Certificates are offered only where available for the selected model.